PW-110 12V 5A Linear Access Control Power Supply

12 V DC, 5 A linear power supply with exit-button and control inputs and NC/NO lock outputs, in a 182 × 79 × 62 mm steel case. 220 V AC input.

  • 12 V DC ±15% output rated 5 A; linear design with ≤ 100 mV ripple
  • PUSH input for an exit button; CONTROL input accepts ±5 to ±15 V signals
  • NC and NO lock outputs for fail-safe and fail-secure locks
  • Self-resetting overload and short-circuit shut-off
  • Gray steel case, 182 × 79 × 62 mm
Output
12 V DC ±15%, 5 A
Input
220 V AC ±20%
Ripple
≤ 100 mV
Control inputs
PUSH (exit button), CONTROL (±5 to ±15 V)
Battery backup
None
Dimensions
182 × 79 × 62 mm
Reply within 24 hours Tested before dispatch Worldwide shipping

12V 5A Linear Access Control Power Supply: overview

PW-110 is a 12 V DC, 5 A linear power supply for access control doors and building intercom systems. Besides powering locks and readers, it acts as a simple lock power controller: a PUSH input accepts an exit button, a CONTROL input takes a ±5 to ±15 V signal from an access controller, and NC and NO outputs feed fail-safe or fail-secure locks.

Linear regulation keeps output ripple at or below 100 mV, and the gray steel case measures 182 × 79 × 62 mm for mounting above the door or in a riser closet. Overloads and short circuits trip a self-resetting protective element: the output shuts off, and once the fault is cleared and the element has cooled for about 10 minutes, the supply returns to normal.

Input is 220 V AC ±20%, so this model is meant for 220–240 V mains regions; for 110/120 V sites, the PW-130 power box accepts 100–260 V AC. There is no battery charging circuit, so specify the PW-130 with its optional battery, or an upstream UPS, where doors must stay powered during outages.

Integration notes

The NC and NO lock terminals carry an unregulated 17 V output, and the C/NO contact is rated for a 1.5 A load; the regulated DC 12 V terminal is rated for 1.2 A. Check each lock's voltage tolerance before using the NC/NO terminals, and size the total load with 25–50% headroom. Operating temperature is –20 to +50 °C.

More features

  • 220 V AC ±20% input; no battery charging circuit

PW-110 specifications

Input & output

Input voltage220 V AC ±20%
Output voltage12 V DC ±15%
Rated output current5 A
Ripple≤ 100 mV
TopologyLinear

Terminals & control

NC / NO lock outputs17 V, unregulated
Lock contact (C/NO) load1.5 A max
DC 12 V output load1.2 A max
PUSH inputSwitch signal (exit button)
CONTROL input±5 V to ±15 V signal

Protection & backup

Overload / short circuitOutput shuts off; resumes once the fault is cleared and the protective element has cooled (about 10 minutes)
Dedicated over-current protection (OCP) circuitNo
Battery chargingNone
Standard batteryNone

Mechanical & environment

HousingSteel, gray
Dimensions182 × 79 × 62 mm
Operating temperature–20 to +50 °C

PW-110 vs PW-120 linear power supplies

ParameterPW-110PW-120
Rated output current5 A3 A
Output voltage12 V DC ±15%12 V DC ±15%
Input voltage220 V AC ±20%220 V AC ±20%
Ripple≤ 100 mV≤ 100 mV
Lock contact (C/NO) load1.5 A max1.5 A max
DC 12 V terminal load1.2 A max1.2 A max
Battery chargingNoneNone
CaseSteel, gray, 182 × 79 × 62 mmSteel, gray, 182 × 79 × 62 mm

Both units share the same case, inputs and terminal ratings; only the rated output current differs.

Specifications can change between production batches. Confirm the current revision with us before placing volume orders.

Ordering options

Quote the SKU that matches your frequency, interface and mounting. Not sure? Send us your controller model and we will pick the variant for you.

SKUConfigurationActions
PW-110 12 V DC 5 A linear access control power supply, 220 V AC input, gray steel case

Where the PW-110 is used

  • Powering a maglock or drop bolt plus reader at a single controlled door
  • Standalone exit-button doors where the supply switches the lock directly
  • Building intercom and door-entry panels in 220–240 V mains regions

PW-110 FAQ

Can PW-110 run on 110/120 V mains?

No. The input is 220 V AC ±20% (about 176–264 V AC). For 110/120 V sites, the PW-130 power box accepts 100–260 V AC.

Does it charge a backup battery?

No. There is no charging circuit or battery terminal, so use an upstream UPS or the PW-130 enclosure with its optional battery if the doors need backup power.

How does it release a lock without a controller?

Wire an exit button to the PUSH input and the lock to the NC or NO output that matches its fail-safe or fail-secure mode. A controller can trigger the same outputs through the CONTROL input with a ±5 to ±15 V signal.

What happens after a short circuit?

The output shuts off to protect the supply. Clear the fault, allow about 10 minutes for the protective element to cool, and the supply resumes normal operation.

How many locks can it power?

Plan against the terminal limits as well as the 5 A rating: 1.5 A on the lock contact and 1.2 A on the DC 12 V terminal. Send us your lock models and we will check the load.

Before you buy

Related buyer guides

Related products

All Locks & Accessories
PW-130

Access Control Power Supply Box, 12V 5A/10A, Tamper Switch

450 × 340 × 90 mm steel power box with a 12 V DC 5 A or 10 A supply, circuit breaker, tamper switch and lid-activated LED. Optional backup battery.

12 V DC ±10%, 5 A or 10 A100–260 V AC, 50–65 HzStandard
Details →
PW-120

12V 3A Linear Access Control Power Supply

12 V DC, 3 A linear power supply for access control doors, with PUSH and CONTROL inputs and NC/NO lock outputs. Gray steel case, 220 V AC input.

12 V DC ±15%, 3 A220 V AC ±20%≤ 100 mV
Details →
EL-190

280 kg (600 lb) Magnetic Lock with Status Output, 12/24 V

Single-door 280 kg (600 lb) maglock with NO/NC status output, a 250 × 47 × 26 mm aluminum-alloy body and a 12 or 24 V DC coil drawing 480/240 mA.

280 kg (600 lb)12 or 24 V DC480 mA @ 12 V / 240 mA @ 24 V
Details →
EL-170

Double Door Magnetic Lock 2 × 280 kg (600 lb) with Status

One 500 mm aluminum body holding two 280 kg (600 lb) magnets for double doors, with an NO/NC status signal output and 12 or 24 V DC operation.

2 × 280 kg (2 × 600 lb)12 or 24 V DC960 mA @ 12 V / 480 mA @ 24 V
Details →
EL-110

Waterproof 280 kg (600 lb) Magnetic Lock with Door Status

Waterproof single-door maglock holding 280 kg (600 lb), with an aluminum-alloy housing, installer-selectable 12/24 V DC coil and a door-status output.

280 kg (600 lb) ±10%12 or 24 V DC ±10%, selectable480 mA @ 12 V / 240 mA @ 24 V
Details →
EL-200

280 kg (600 lb) Single Door Magnetic Lock, 12/24 V DC

Fail-safe 280 kg (600 lb) single-door maglock with a 250 × 47 × 26 mm aluminum-alloy body, 12 or 24 V DC coil (480/240 mA) and hex-socket screws.

280 kg (600 lb)12 or 24 V DC480 mA @ 12 V / 240 mA @ 24 V
Details →
EL-120

Stainless Steel Waterproof 280 kg (600 lb) Magnetic Lock

Compact 210 mm stainless-steel maglock with 280 kg (600 lb) holding force, waterproof construction, selectable 12/24 V DC coil and a door-status output.

280 kg (600 lb) ±10%12 or 24 V DC ±10%, selectable460 mA @ 12 V / 230 mA @ 24 V
Details →

Get pricing for the PW-110

Send your card type, interface and quantity. You get a quote, lead time and compatibility notes within 24 hours — samples available for most items.

Email us
sales@valenid.com

Request a quote

Tell us what you need — an engineer replies within 24 hours with pricing, lead time and compatibility notes.

We reply within 24 hours on working days. Your details are used only to answer this inquiry — see our privacy policy.