Apartment, Multifamily & Rental Property Access Control
Apartment building access control hardware: anti-clone readers with matched fob sets, QR visitor codes, 4G controllers for rentals and UHF tags for gates.
Send us your controller model, card type and install environment. We'll shortlist compatible hardware and quote within 24 hours.
12 V DC, 5 A linear power supply with exit-button and control inputs and NC/NO lock outputs, in a 182 × 79 × 62 mm steel case. 220 V AC input.
PW-110 is a 12 V DC, 5 A linear power supply for access control doors and building intercom systems. Besides powering locks and readers, it acts as a simple lock power controller: a PUSH input accepts an exit button, a CONTROL input takes a ±5 to ±15 V signal from an access controller, and NC and NO outputs feed fail-safe or fail-secure locks.
Linear regulation keeps output ripple at or below 100 mV, and the gray steel case measures 182 × 79 × 62 mm for mounting above the door or in a riser closet. Overloads and short circuits trip a self-resetting protective element: the output shuts off, and once the fault is cleared and the element has cooled for about 10 minutes, the supply returns to normal.
Input is 220 V AC ±20%, so this model is meant for 220–240 V mains regions; for 110/120 V sites, the PW-130 power box accepts 100–260 V AC. There is no battery charging circuit, so specify the PW-130 with its optional battery, or an upstream UPS, where doors must stay powered during outages.
The NC and NO lock terminals carry an unregulated 17 V output, and the C/NO contact is rated for a 1.5 A load; the regulated DC 12 V terminal is rated for 1.2 A. Check each lock's voltage tolerance before using the NC/NO terminals, and size the total load with 25–50% headroom. Operating temperature is –20 to +50 °C.
| Input voltage | 220 V AC ±20% |
|---|---|
| Output voltage | 12 V DC ±15% |
| Rated output current | 5 A |
| Ripple | ≤ 100 mV |
| Topology | Linear |
| NC / NO lock outputs | 17 V, unregulated |
|---|---|
| Lock contact (C/NO) load | 1.5 A max |
| DC 12 V output load | 1.2 A max |
| PUSH input | Switch signal (exit button) |
| CONTROL input | ±5 V to ±15 V signal |
| Overload / short circuit | Output shuts off; resumes once the fault is cleared and the protective element has cooled (about 10 minutes) |
|---|---|
| Dedicated over-current protection (OCP) circuit | No |
| Battery charging | None |
| Standard battery | None |
| Housing | Steel, gray |
|---|---|
| Dimensions | 182 × 79 × 62 mm |
| Operating temperature | –20 to +50 °C |
| Parameter | PW-110 | PW-120 |
|---|---|---|
| Rated output current | 5 A | 3 A |
| Output voltage | 12 V DC ±15% | 12 V DC ±15% |
| Input voltage | 220 V AC ±20% | 220 V AC ±20% |
| Ripple | ≤ 100 mV | ≤ 100 mV |
| Lock contact (C/NO) load | 1.5 A max | 1.5 A max |
| DC 12 V terminal load | 1.2 A max | 1.2 A max |
| Battery charging | None | None |
| Case | Steel, gray, 182 × 79 × 62 mm | Steel, gray, 182 × 79 × 62 mm |
Both units share the same case, inputs and terminal ratings; only the rated output current differs.
Specifications can change between production batches. Confirm the current revision with us before placing volume orders.
Quote the SKU that matches your frequency, interface and mounting. Not sure? Send us your controller model and we will pick the variant for you.
| SKU | Configuration | Actions |
|---|---|---|
| PW-110 | 12 V DC 5 A linear access control power supply, 220 V AC input, gray steel case |
Apartment building access control hardware: anti-clone readers with matched fob sets, QR visitor codes, 4G controllers for rentals and UHF tags for gates.
No. The input is 220 V AC ±20% (about 176–264 V AC). For 110/120 V sites, the PW-130 power box accepts 100–260 V AC.
No. There is no charging circuit or battery terminal, so use an upstream UPS or the PW-130 enclosure with its optional battery if the doors need backup power.
Wire an exit button to the PUSH input and the lock to the NC or NO output that matches its fail-safe or fail-secure mode. A controller can trigger the same outputs through the CONTROL input with a ±5 to ±15 V signal.
The output shuts off to protect the supply. Clear the fault, allow about 10 minutes for the protective element to cool, and the supply resumes normal operation.
Plan against the terminal limits as well as the 5 A rating: 1.5 A on the lock contact and 1.2 A on the DC 12 V terminal. Send us your lock models and we will check the load.
Maglock wiring with dry-relay COM/NC: keypad and reader diagrams, REX signals, approved egress release paths and manufacturer-specific suppression.
A fail-safe lock releases when power is cut; a fail-secure lock stays locked. Learn which to use per door, how to wire NO/NC, and what egress codes expect.
Program a standalone access control keypad: enter programming mode, change the master code, add card and PIN users, set relay time, reset and wire it.
450 × 340 × 90 mm steel power box with a 12 V DC 5 A or 10 A supply, circuit breaker, tamper switch and lid-activated LED. Optional backup battery.
12 V DC, 3 A linear power supply for access control doors, with PUSH and CONTROL inputs and NC/NO lock outputs. Gray steel case, 220 V AC input.
Single-door 280 kg (600 lb) maglock with NO/NC status output, a 250 × 47 × 26 mm aluminum-alloy body and a 12 or 24 V DC coil drawing 480/240 mA.
One 500 mm aluminum body holding two 280 kg (600 lb) magnets for double doors, with an NO/NC status signal output and 12 or 24 V DC operation.
Waterproof single-door maglock holding 280 kg (600 lb), with an aluminum-alloy housing, installer-selectable 12/24 V DC coil and a door-status output.
Fail-safe 280 kg (600 lb) single-door maglock with a 250 × 47 × 26 mm aluminum-alloy body, 12 or 24 V DC coil (480/240 mA) and hex-socket screws.
Fail-safe double-door maglock: two 280 kg (600 lb) magnets in one 500 × 47 × 26 mm aluminum body, 12 or 24 V DC, without signal output.
Compact 210 mm stainless-steel maglock with 280 kg (600 lb) holding force, waterproof construction, selectable 12/24 V DC coil and a door-status output.
Send your card type, interface and quantity. You get a quote, lead time and compatibility notes within 24 hours — samples available for most items.