Apartment, Multifamily & Rental Property Access Control
Apartment building access control hardware: anti-clone readers with matched fob sets, QR visitor codes, 4G controllers for rentals and UHF tags for gates.
Send us your controller model, card type and install environment. We'll shortlist compatible hardware and quote within 24 hours.
13.56 MHz module built around the LEGIC SM-4200 chip that reads and writes LEGIC cards and returns MIFARE, iCLASS, FeliCa and ICODE UIDs over TTL serial.
The XM-110 is a 13.56 MHz reader/writer module for OEMs adding LEGIC card handling to their own hardware: smart locks, handheld and tablet terminals, access readers, and parcel or logistics devices. It is built around the LEGIC SM-4200 reader chip (details on request) and performs both read and write operations on LEGIC credentials. For other card types it returns the unique identifier — the UID of FeliCa, MIFARE and ICODE cards and the card serial number (CSN) of iCLASS cards — so a mixed badge estate can still be identified by one module.
Protocol support covers ISO/IEC 14443A, ISO/IEC 14443B and ISO/IEC 15693. The host can set and query the module address, baud rate and serial number by command, which is useful when provisioning devices or tracing them in the field. Read distance is more than 20 mm, depending on the credential and the installation.
The module runs from 5 V DC (±5%) and draws less than 200 mA. It talks TTL serial at 9600–115200 bps, set by command and defaulting to 115200 bps. Connections are spread over three headers: J2 carries RESET, receive (CRX), transmit (CTX), GND and VCC; J1 provides an LED pin; and J3 offers GND plus an additional TX line. The board measures 38 × 18 × 10.5 mm. It operates from –10 to +70 °C at 15–90% humidity and can be stored from –20 to +80 °C. No certifications are listed, so compliance is assessed on the finished product.
Third-party credential and platform names on this page are trademarks of their respective owners and are used only to describe compatibility.
| Operating frequency | 13.56 MHz |
|---|---|
| Reader chip | LEGIC SM-4200 |
| LEGIC credentials | Read and write |
| Other credentials | UID read: FeliCa, MIFARE, ICODE; card serial number (CSN) read: iCLASS |
| Protocols | ISO/IEC 14443A, ISO/IEC 14443B, ISO/IEC 15693 |
| Read distance | > 20 mm (depends on credential and environment) |
| Host interface | TTL serial (UART) |
|---|---|
| Baud rate | 9600–115200 bps, set by command (default 115200 bps) |
| Configurable parameters | Module address, baud rate, serial number (set and read by command) |
| Connectors | J1: 3 pins (LED); J2: 5 pins (power, reset, UART); J3: 2 pins (GND, TX) |
| Supply voltage | 5 V DC ±5% |
|---|---|
| Operating current | < 200 mA |
| Dimensions | 38 × 18 × 10.5 mm (stated tolerance ±3 mm) |
|---|---|
| Operating temperature | –10 to +70 °C (+14 to +158 °F) |
| Storage temperature | –20 to +80 °C (–4 to +176 °F) |
| Operating humidity | 15–90% RH |
| Certifications | None listed for the module |
|---|
| Pin | Signal | Function |
|---|---|---|
| J1-1 | NC | Not connected |
| J1-2 | NC | Not connected |
| J1-3 | LED | LED signal |
| J2-1 | RESET | Module reset |
| J2-2 | CRX | Serial receive (module input) |
| J2-3 | CTX | Serial transmit (module output) |
| J2-4 | GND | Ground |
| J2-5 | VCC | Power input, 5 V DC |
| J3-1 | GND | Ground |
| J3-2 | TX | Additional transmit data line |
Three headers: J1 (LED), J2 (power, reset and serial), J3 (additional TX). Confirm the J3 TX function with the command documentation.
Specifications can change between production batches. Confirm the current revision with us before placing volume orders.
Quote the SKU that matches your frequency, interface and mounting. Not sure? Send us your controller model and we will pick the variant for you.
| SKU | Configuration | Actions |
|---|---|---|
| XM-110-LG-T | LEGIC SM-4200-based 13.56 MHz reader/writer module; TTL serial; 5 V DC |
Apartment building access control hardware: anti-clone readers with matched fob sets, QR visitor codes, 4G controllers for rentals and UHF tags for gates.
It reads and writes LEGIC credentials. For FeliCa, MIFARE, ICODE and iCLASS cards it returns the UID or card serial number only.
The module is built around the LEGIC SM-4200 reader chip. Further chip and firmware details are available on request.
TTL serial at 9600–115200 bps, set by command; the default is 115200 bps. The module address and serial number can also be set and read.
More than 20 mm. Actual distance depends on the credential type and the installation environment.
No certifications are listed for the module, so compliance is assessed on your finished product.
Compare Wiegand, OSDP and RS485 reader interfaces: wiring, cable limits, AES-128 Secure Channel and steps for a compatible access-control migration.
125 kHz cards are cheap but easy to clone; 13.56 MHz cards add memory and, on DESFire-class chips, AES security. Compare range, chips, security and migration.
Wiegand 26-bit is an even parity bit, 8-bit facility code, 16-bit card number and odd parity bit. Convert card numbers to hex and back with the calculator.
30 × 16 mm OEM module that reads 125 kHz EM and HID Prox-compatible cards plus MIFARE, DESFire, FeliCa and ICODE at 13.56 MHz, over 3.3 V UART or USB.
Our most complete module: BLE 5.1 plus iCLASS, iCLASS SE, Seos and HID Prox compatibility, EM, MIFARE/DESFire/FeliCa cards and NFC mobile credentials.
30 × 30 mm USB module that reads and writes LEGIC advant and LEGIC prime and also handles MIFARE, DESFire, MIFARE Plus, NTAG, FeliCa and ICODE credentials.
Dual-frequency OEM module listing iCLASS, iCLASS SE, Seos and HID Prox compatibility, EM and MIFARE/DESFire cards, and NFC mobile credentials incl. Apple Wallet.
Dual-frequency module with BLE 5.1 that reads HID Prox-compatible and EM credentials plus MIFARE, DESFire, FeliCa and ICODE, over 3.3 V UART or USB.
Dual-frequency module with BLE 5.1 for Bluetooth virtual cards and data pass-through, reading EM4100-family, MIFARE, DESFire, FeliCa and ICODE credentials.
HF-only OEM module listing iCLASS, iCLASS SE and Seos compatibility alongside MIFARE, DESFire, FeliCa and ICODE, with 3.3 V UART and USB on a 30 × 16 mm board.
Dual-frequency OEM module for EM4100-family and 13.56 MHz MIFARE, DESFire, FeliCa and ICODE credentials, without HID formats, on a 30 × 16 × 8.8 mm board.
Send your card type, interface and quantity. You get a quote, lead time and compatibility notes within 24 hours — samples available for most items.